我用stm32f407的TIM1和TIM8级联组成32位计数器,TIM1作为主计数器,TIM8作为从计数器配置代码如下
TIM_TimeBaseInitTypeDef TIM_TimeBaseInitStructure;
RCC_APB2PeriphClockCmd(STD_TIM1_CLK, ENABLE); ///使能标准频率时钟1
RCC_APB2PeriphClockCmd(STD_TIM2_CLK, ENABLE); ///使能标准频率时钟2
//标准频率定时器1配置
TIM_TimeBaseInitStructure.TIM_Period = 0xFFFF; //自动重装载值
TIM_TimeBaseInitStructure.TIM_Prescaler = 0; //定时器分频
TIM_TimeBaseInitStructure.TIM_CounterMode = TIM_CounterMode_Up; //向上计数模式
TIM_TimeBaseInitStructure.TIM_ClockDivision = TIM_CKD_DIV1;
TIM_TimeBaseInit(STD_TIM1, &TIM_TimeBaseInitStructure);
TIM_SetCounter(STD_TIM1, 0); // 清零计数器 CNT
TIM_SelectOutputTrigger(STD_TIM1, TIM_TRGOSource_Update);//Tim1 更新输出作为触发信号
//标准频率定时器2配置
TIM_TimeBaseInitStructure.TIM_Period = 0xFFFF; //自动重装载值
TIM_TimeBaseInitStructure.TIM_Prescaler = 0; //定时器分频
TIM_TimeBaseInitStructure.TIM_CounterMode = TIM_CounterMode_Up; //向上计数模式
TIM_TimeBaseInitStructure.TIM_ClockDivision = TIM_CKD_DIV1;
TIM_TimeBaseInit(STD_TIM2, &TIM_TimeBaseInitStructure);
TIM_SetCounter(STD_TIM2, 0); // 清零计数器 CNT
TIM_SelectMasterSlaveMode (STD_TIM2, TIM_MasterSlaveMode_Enable);// 主从模式 MSM
TIM_SelectSlaveMode (STD_TIM2, TIM_SlaveMode_External1);// 从模式外部触发模式
TIM_SelectInputTrigger (STD_TIM2, TIM_TS_ITR0);// 触发选择,ITR0 即 TIM1
TIM_Cmd(STD_TIM2, ENABLE);
其中STD_TIM1是TIM1,STD_TIM2是TIM8.
我在main函数中启动TIM1后,用另一定时器TIM2定时1秒,在TIM2中断中用TIM_GetCounter(STD_TIM2) * 65536 + TIM_GetCounter(STD_TIM1)语句读出的数据是4217116,
但是TIM1和TIM8的时基都应该是168M,并且我没有配置分频,请问这个的原因是什么?
我用TIM_GetCounter(STD_TIM2) * 65536 * 4 + TIM_GetCounter(STD_TIM1)才能得到168000000的计数值。
友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
一周热门 更多>